How to troubleshoot an aqua rite filter pump?

How to troubleshoot an aqua rite filter pump?

Check for damaged or cut wire. Page 8 If LED is flashing, wait 60 seconds after starting filter pump. Check for possible turbulence inside of flow T. Installation requires 12 inches of straight pipe before flow switch. There should be no elbow after the flow switch. O HAYWARD

What should I do if my Aqua rite light is flashing?

Page 8 If LED is flashing, wait 60 seconds after starting filter pump. Check for possible turbulence inside of flow T. Installation requires 12 inches of straight pipe before flow switch. There should be no elbow after the flow switch. O HAYWARD No LED’s/LCD display Verify 220-240 VAC or 115-125 VAC at input terminal TBI.

Where can I find the Aqua rite diagnostics manual?

Aqua Rite & Aqua Rite XL Diagnostics Manual AQUA RITE ELECTRONIC CHLORINE GENERÀTOR CELL Turbo Cell & Control Electronics Software Revision 1.50 O HAYWARD Copyright 2009 Hayward Industries Inc.

When do I need to replace my Aqua rite transformer?

The readings should be 2.0-2.9 Ohms. If the readings of either of the two measurements are not 2.0 — 2.9 Ohms, the transformer is faulty and should be replaced If measurements are OK, go to step F. O HAYWARD No LED’ Verify 18-33 VDC between black & red wires on main board step G DCV OFF . ON If no/low voltage replace rectifiers.

How to troubleshoot an aqua rite with a fuse?

Power LED Not On 1 Make sure that either 120VAC or 240VAC input power is connected to the proper screw terminals at the Aqua Rite control. 2 Verify input voltage with a voltmeter 3 If there is input power, the fuse may have blown. 4 The Aqua Rite is protected by a 20 amp mini ATO fuse located on the circuit board above the cell connector.

What should I do if my Aqua rite pump is not working?

The temperature of the pool water is too high or too low to operate. Override this by moving the Main Switch to Super Chlorinate. The Aqua Rite runs at maximum out for for the remainder of the current pump cycle or for 24 hours, whichever comes first.

What’s the best way to troubleshoot an aqua rite cell?

(GLX-CELLSTAND) Step 1: Use a water hose to dislodge small debris. Step 2: Use a non-metal (plastic or wood), non-abrasive tool to dislodge minor calcium buildup and small debris. Step 3: Use a solution of water and Muriatic acid. Stand the cell vertically in the solution. M’x 1 part acid to 4 parts water.