How big is a suburban SF Q furnace?
How big is a suburban SF Q furnace?
Suburban’s SF-Q Series furnaces provide maximum heating performance in a ducted unit, with capacities from 20,000 to 40,000 BTU/h. Yet, at only 7 1/2 inches high, they can be easily installed in areas that might otherwise be left unused.
What should I do if my Suburban furnace wont ignite?
Here’s what I’ve tried so far prior to giving up and drinking but that time is getting close lol 1) Turn T stat on and raise temp, so it delays then fan runs, gas valve opens (smell gas outside) but it failed to light after a couple tries then locks out and gas valve closed.
What kind of power does a suburban furnace use?
Suburban furnaces operate on 12-volt DC power which is supplied either by a 12-volt battery or a converter system. A recreational vehicle furnace that is specifically designed for “park model” trailers operates on 120 volts AC. These are designed and tested under the same standards as the 12-volt models.
How big is the manifold on a suburban furnace?
27,300 CLARIFIQUE MANIFOLD PRESSURE 10.0” W.C. PRESSION TUBULURE ORIFICE SIZE #51 DIMENSION DE L’INJECTEUR TYPE OF GAS LP ESPECE DE GAZ MODEl brEaKDOWn SF-35F Suburban Furnace 35,000 BTU Front Gas SErial # brEaKDOWn 093102771 Year of MFG (2009) Week of YR (31) Sequential SR#(02771) 4 GEnEral SErViCE inFOrMaTiOn GAS SUPPLY PRESSURE REQUIREMENTS
What kind of burner does the SF-Q have?
For design flexibility, all SF-Q Models feature identical cabinet dimensions and feature quiet, multi-ported stainless steel burners, sealed forced-draft combustion, automatic direct spark ignition and low amp draw. Specifications Subject to Change without Notice. For Warranty information, CLICK HERE.
How tall are the ducts on a SFQ RV?
Yet, at only 7 1/2 inches high, they can be easily installed in areas that might otherwise be left unused. With nine duct connection choices (top, front, side and bottom), as well as models for interior and exterior installation and service, the SF-Q offers almost unlimited design flexibility in mid-size and large RVs.
Suburban’s SF-Q Series furnaces provide maximum heating performance in a ducted unit, with capacities from 20,000 to 40,000 BTU/h. Yet, at only 7 1/2 inches high, they can be easily installed in areas that might otherwise be left unused.
What kind of furnace does a suburban use?
3 FurnaCE inTrODuCTiOn Suburban furnaces installed in recreational vehicles are classified as Direct Vent Sealed Combustion Furnaces. A forced draft furnace utilizes a sealed combustion chamber which is vented to the outside atmosphere. The intake air for combustion is also taken from outdoors and is completely isolated from the room air.
27,300 CLARIFIQUE MANIFOLD PRESSURE 10.0” W.C. PRESSION TUBULURE ORIFICE SIZE #51 DIMENSION DE L’INJECTEUR TYPE OF GAS LP ESPECE DE GAZ MODEl brEaKDOWn SF-35F Suburban Furnace 35,000 BTU Front Gas SErial # brEaKDOWn 093102771 Year of MFG (2009) Week of YR (31) Sequential SR#(02771) 4 GEnEral SErViCE inFOrMaTiOn GAS SUPPLY PRESSURE REQUIREMENTS
Where is the serial number on a suburban furnace?
MODEl & SErial nuMbEr inFOrMaTiOn Model and Serial Numbers for Suburban Furnaces are located on a Data Plate attached to the furnace assembly. Below is an example: MODEl nO. / nuMÉrO DE MODÉlE SF-35F SErial nO./ nuMÉrO DE SÉriE 093102771 STOCK NO.2332 INPUT BTU/HR.35,000 @ DEBIT 10.0” W.C. CALORIFIQUE OUTPUT BTU/HR. 27,300