Can you still get parts for a Potterton boiler?
Can you still get parts for a Potterton boiler?
Potterton boiler spares from PlumbNation are available to buy for all Potterton appliances when you need to maintain your boiler due to a failed part. PlumbNation provides boiler spare parts with a number of delivery options from next day delivery to nominated timed delivery. …
Is Potterton Suprima a condensing boiler?
The Potterton Suprima 50L has a SAP seasonal efficiency rating of 78.1%. The Suprima 50L is a Non-Condensing Conventional boiler with a maximum power output of 14.7kw that uses Gas as its fuel source.
How big does a Potterton Suprima boiler get?
Potterton suprima were a very good boiler in their time, they were small and compact and would fit nicely inside a kitchen cupboard. They came in many heat output sizes from 30,000 BTUs right up to 120000 BTUs and all in the same size case.
Are there any problems with the Potterton Suprima?
They came in many heat output sizes from 30,000 BTUs right up to 120000 BTUs and all in the same size case. The 120s were recalled a few times due to problems and eventually withdrawn, but all in all, they were a good boiler. The Potterton suprima had its faults though and one of them was the PCB or otherwise known as the printed circuit board.
Are there any problems with the Potterton 120?
The 120s were recalled a few times due to problems and eventually withdrawn, but all in all, they were a good boiler. The Potterton suprima had its faults though and one of them was the PCB or otherwise known as the printed circuit board.
What does flashing red mean on Potterton Suprima boiler?
I can’t remember now.) The Potterton Suprima Replacement PCB Kit manual says that flashing red 3 times/sec indicates an air pressure switch (APS) fault or a flow switch fault. We opened the boiler up to check if a flow switch was fitted (sometimes called a dry fire switch) but there was none on this boiler.
When was the Potterton Suprima gas boiler made?
It clearly still had the old style circuit board, again one of the earlier circuit boards fitted to the Potterton Suprima, with a membrane panel which has to be pressed to re-set the boiler if it locks out. The data plate carried a “00” year code indicating it was manufactured in 2000.
I can’t remember now.) The Potterton Suprima Replacement PCB Kit manual says that flashing red 3 times/sec indicates an air pressure switch (APS) fault or a flow switch fault. We opened the boiler up to check if a flow switch was fitted (sometimes called a dry fire switch) but there was none on this boiler.
Are there any problems with the Potterton profile boiler?
A relatively common issue with older Potterton boiler models such as the Potterton Promax, Suprima and Profile models is an issue where the heating works but there is no hot water. A similar, but slightly less common problem is the other way round with hot water working but no central heating.
When did the Potterton Suprima circuit board come out?
The data plate carried a “00” year code indicating it was manufactured in 2000. We removed the screw which allows the control panel to flip down and inspected the board, finding the classical darkened scorch mark which is typical of Potterton Suprima circuit boards of this type.