What is a Gledhill Boilermate 2000?
What is a Gledhill Boilermate 2000?
The BoilerMate 2000 is designed to provide improved space heating and mains pressure hot water when coupled to any remotely sited condensing or none condensing. A report by the Cranfield Institute of Technology found that this system gives a potential for energy savings of up to 15%.
What can replace Boilermate?
Combination boilers are not normally suited to properties where boilermates are fitted and the most common replacement would be with an unvented hot water cylinder. These are far more manageable than the boilermate and depending on the size should fit in the same space as the redundant thermal store too.
Is a thermal store vented?
Systems can be vented or sealed depending on heat sources used. Equally different heat sources can be separated through coils within the thermal store, meaning some vented or sealed. 12. A thermal store enables you to use low temperature heating circuit which typically save homeowners 20% off there heating bills.
What are the functions of a Gledhill boilermate 2000?
One of the most technologically advanced water heating and storage systems available, your Gledhill BoilerMate 2000 is designed to fulfil four basic needs : 1. Provide rapid heat up of your property whenever you switch your heating on 2. supply heating and hot water more efficiently than conventional systems 3.
Is the Gledhill BP boilermate a central heating unit?
Secondly, the Boilermate BP does not output to central heating. Whereas the older unit would send pre-heated water off to the radiators on demand the new one doesn’t. There is no central heating function to the BP model.
How old is boiler mate from Gledhill response?
It might be worth checking out Gledhill response to get a boiler mate specialist to take a look if you don’t fancy shelling all that money out to replace it [/QUOTe the op has the original Boiler mate (20 years old), def sounds like the blending valve has scaled up.
What do you need to know about boilermate 2000?
boilermate user instructions user instructions your boilermate 2000 is operating under ‘sWitch’ conditions as the hot water temperature will be higher than in its normal operating condition. Operation of ‘SWITCH’ is simple, just click to position 1 if you need hot water only or position 2 for hot water and heating
One of the most technologically advanced water heating and storage systems available, your Gledhill BoilerMate 2000 is designed to fulfil four basic needs : 1. Provide rapid heat up of your property whenever you switch your heating on 2. supply heating and hot water more efficiently than conventional systems 3.
Secondly, the Boilermate BP does not output to central heating. Whereas the older unit would send pre-heated water off to the radiators on demand the new one doesn’t. There is no central heating function to the BP model.
How old is the boilermate heating and cooling system?
In short, the house has an original Boilermate system (20 years old) and a less than 2 yr old Worcester 18 Ri. The heating is ok (controlled by a Drayton1+RF), but the hot water seems to have a few issues. A local plumber came in and found 2 leaks, a partly fried circuit board and (probably) a malfunctioning mixing valve.
It might be worth checking out Gledhill response to get a boiler mate specialist to take a look if you don’t fancy shelling all that money out to replace it [/QUOTe the op has the original Boiler mate (20 years old), def sounds like the blending valve has scaled up.