How to restart a potterton Suprima boiler?

How to restart a potterton Suprima boiler?

Press the reset button for 10 seconds, the LED will flash Orange once then return to normal operation.

What does a flashing red light mean on a potterton boiler?

The red light usually flashes fast. A new gas valve takes about an hour to fit, test and adjust. If you’d like me to fix your Suprima, call or text me on 07866 766364.

Are there any problems with the Potterton Suprima?

They came in many heat output sizes from 30,000 BTUs right up to 120000 BTUs and all in the same size case. The 120s were recalled a few times due to problems and eventually withdrawn, but all in all, they were a good boiler. The Potterton suprima had its faults though and one of them was the PCB or otherwise known as the printed circuit board.

Is the Potterton Suprima boiler still a good boiler?

This used to make the boiler go into lockout. Everything needed comes in the box. All in all the Potterton suprima was and still is a good boiler compared to today’s condensing boiler. Potterton suprima were a very good boiler in their time, they were small and compact and would fit nicely inside a kitchen cupboard.

When did the Potterton Suprima circuit board come out?

The data plate carried a “00” year code indicating it was manufactured in 2000. We removed the screw which allows the control panel to flip down and inspected the board, finding the classical darkened scorch mark which is typical of Potterton Suprima circuit boards of this type.

Are there any problems with the Potterton 120?

The 120s were recalled a few times due to problems and eventually withdrawn, but all in all, they were a good boiler. The Potterton suprima had its faults though and one of them was the PCB or otherwise known as the printed circuit board.

What is the phone number for Potterton Suprima 30-100l?

POTTERTON G.C. No. 41 590 42 9016BOILER CODE No. ALVG101 0003 SUPRIMA 30 L SUP263A

How to tell if a Potterton Suprima he 80 is faulty?

If the pcb immediately shows red lights for ignition lockout then the PCB is at fault so change it and try again. Second If the boiler goes through its firing sequence 5 times and then goes to lockout, check to see if in each of the 5 sequences could a flame be seen through the spy glass in the front of the boiler or not.

What are the installation instructions for Suprima 30-80?

The models covered by these instructions are:- Suprima 30 – G.C. No. 41 607 75 Suprima 40 – G.C. No. 41 607 76 Suprima 50 – G.C. No. 41 607 77 Suprima 60 – G.C. No. 41 607 78 Suprima 70 – G.C. No. 41 607 79 Suprima 80 – G.C. No. 41 607 80

What was the problem with the Potterton Suprima boiler?

The problem was because the boiler was so small the PCB which is located on the right-hand side if you are facing the boiler used to start to overheat when you looked at the PCB you could see burn marks. This used to make the boiler go into lockout. You could reset the boiler then it would work for a while then back to lockout. In the end,