What Do Baxi Error Codes E133 or E28 Mean? If your boiler has shut down and is showing error code E133 or E28, then your condensate pipe may be frozen. Please follow these steps to get your boiler up and running again: Switch your boiler off at the control panel, and turn off the electricity at the wall.

What to do if your boiler has an error code E133?

If your boiler has shut down and is showing error code E133 or E28, then your condensate pipe may be frozen. Please follow these steps to get your boiler up and running again: Switch your boiler off at the control panel, and turn off the electricity at the wall.

Why are there two error codes on my Baxi boiler?

If you’re seeing either of these two error codes on your Baxi boiler, this is due to your condensate pipe being frozen. In the cold winter months this can happen easily as the condensate pipe runs outside.

Can a Baxi duo TEC boiler go to E133?

Below you can see a video of a E133 Baxi Duo Tec boiler under fault condition. In this case the boiler would not fire up at all. The pump and fan would come on at full speed and there would be audible click / clang noise.The noise would happen exactly 3 times and then boiler would go to E133 error code.

What to do with Baxi E133 error code?

GA boilers – What to do with Baxi E133 error code. Want to learn more? Check out our product training courses here www.baxitraining.co.uk Need technical support? Call our Baxi Customer Support technical helpline on 0344 871 15 Loading…

How to troubleshoot a Baxi Luna HT boiler?

Flame Sensor is not sensing: 1- Check polarity and ground from the boiler back to the circuit breaker 2- Check for 3-5 micro amps going to the board 3- If you do not have 3-5 micro amps try cleaning the flame sensor Note: Do not clean the flame sensor using sandpaper as it may damage the protective coating.

If your boiler has shut down and is showing error code E133 or E28, then your condensate pipe may be frozen. Please follow these steps to get your boiler up and running again: Switch your boiler off at the control panel, and turn off the electricity at the wall.

Below you can see a video of a E133 Baxi Duo Tec boiler under fault condition. In this case the boiler would not fire up at all. The pump and fan would come on at full speed and there would be audible click / clang noise.The noise would happen exactly 3 times and then boiler would go to E133 error code.