What kind of boiler does Potterton Puma have?

What kind of boiler does Potterton Puma have?

The Potterton Puma range of boilers are fully automatic, wall mounted, fan assisted, room sealed combination boilers, designed to operate on Natural Gas only. The range of consists of permanent pilot and electronic versions in both 24 kW and 29 kW (100,000Btu/h) outputs.

How many kW does a puma 80E and Saver have?

The range of consists of permanent pilot and electronic versions in both 24 kW and 29 kW (100,000Btu/h) outputs. The 80, 80e and Saver models adjust automatically to provide central heating outputs between 24 kW (81,880 Btu/h) and 10.4 kW (35,480 Btu/h) to suit the system requirements.

What are the installation instructions for a puma 80E boiler?

Part No.27/18810 – 03 Puma 80 – G.C. No. 47 590 10 Puma 80e – G.C. No. 47 590 11 Puma Saver – G.C. No. 47 393 01 Installation & Service Instructions Puma 80, 80e & Saver Wall Mounted, Fanned, Room Sealed Combination Boiler THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS 1994 (as amended).

The Potterton Puma range of boilers are fully automatic, wall mounted, fan assisted, room sealed combination boilers, designed to operate on Natural Gas only. The range of consists of permanent pilot and electronic versions in both 24 kW and 29 kW (100,000Btu/h) outputs.

Part No.27/18810 – 03 Puma 80 – G.C. No. 47 590 10 Puma 80e – G.C. No. 47 590 11 Puma Saver – G.C. No. 47 393 01 Installation & Service Instructions Puma 80, 80e & Saver Wall Mounted, Fanned, Room Sealed Combination Boiler THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS 1994 (as amended).

The range of consists of permanent pilot and electronic versions in both 24 kW and 29 kW (100,000Btu/h) outputs. The 80, 80e and Saver models adjust automatically to provide central heating outputs between 24 kW (81,880 Btu/h) and 10.4 kW (35,480 Btu/h) to suit the system requirements.

What kind of boiler does Potterton Puma 80E use?

Potterton Puma 80e Combination Boiler Fault Customer reported that the boiler was locking out and the pressure kept dropping The Potterton Puma 80e and Puma 100e boilers and the Puma 80 and Puma 100 permanent pilot combi boilers all use a similar expansion vessel and 3 bar pressure relief safety valve.

Where is the bleed valve on a puma boiler?

The Puma boiler has a small bleed valve which can be used to drop the pressure. It’s fitted on the flow pipe just below the diverter valve assembly. The pressure relief safety valve on this boiler was slowly letting by so we changed it too and then raised the system pressure to just over 1 bar.

How do you Drop the pressure on a puma boiler?

Dropping the pressure by draining water from a drain cock may be more effort but it saves changing the safety valve. The Puma boiler has a small bleed valve which can be used to drop the pressure. It’s fitted on the flow pipe just below the diverter valve assembly.

What kind of padding is on Puma ignite?

The Puma Ignite features a standard tongue design with 75% of it padded with foam. The foam padding is placed behind the laces, which prevents pressure from the laces. The tongue is very slim and features a suede piece at the top. Reviewers found the tongue design to create a soft feeling against the skin.

What causes gas to go out in Potterton boiler?

1. No electrical supply to burner. Pilot established – main burner does not light. 2. On/off switch is in ‘OFF’ position. 3. Boiler thermostat set too low. 4. Faulty thermostat or connections. 5. Faulty gas control valve. Main burner remains alight when thermostat satisfied. 1. Faulty thermostat. 2. Faulty gas control valve.

Are there any problems with the Potterton boiler?

#1 Problem: Low Boiler Pressure (E119 Fault Code) Low boiler pressure is a very common Potterton boiler problem that occurs in all boilers and not just the Potterton models. If your Potterton boilers pressures drop too low, it will stop working and display the E119 error code.

Why did Potterton Suprima boiler shut down after 15 minutes?

Potterton Suprima boiler shuts down after 15 minutes, then “dead” for hours with no lights before working again We’ve added this fault because the way it presented was unusual. Our customer reported that the boiler would fire normally in the morning for about 15 minutes before shutting down.

#1 Problem: Low Boiler Pressure (E119 Fault Code) Low boiler pressure is a very common Potterton boiler problem that occurs in all boilers and not just the Potterton models. If your Potterton boilers pressures drop too low, it will stop working and display the E119 error code.

How many kW does a puma 100E heater use?

The 100 and 100e models adjust automatically to provide central heating outputs between 29 kW (98,980 Btu/h) and 11.5 kW (39,235 Btu/h) to suit the system requirements. Domestic hot water has priority over the central heating system and is generated instantaneously within the appliance.

Are there any problems with the Potterton profile boiler?

A relatively common issue with older Potterton boiler models such as the Potterton Promax, Suprima and Profile models is an issue where the heating works but there is no hot water. A similar, but slightly less common problem is the other way round with hot water working but no central heating.

The 100 and 100e models adjust automatically to provide central heating outputs between 29 kW (98,980 Btu/h) and 11.5 kW (39,235 Btu/h) to suit the system requirements. Domestic hot water has priority over the central heating system and is generated instantaneously within the appliance.

What causes an error code E125 on a Potterton boiler?

Blockage – A blockage somewhere in your central heating is preventing water from circulating properly. This is usually caused by a sludge build-up. On your Potterton boiler, this is most likely to be indicated by error code E125 or E193 showing up on your display.

What is the efficiency rating of a Potterton profile 100E boiler?

The Potterton Profile 100e has a SAP seasonal efficiency rating of 73.9%. The Profile 100e is a Non-Condensing Conventional boiler with a maximum power output of 29.3kw that uses Gas as its fuel source. We recommend that you upgrade to a new, more efficient boiler to help reduce fuel bills and carbon dioxide emissions.

How many kW does a Potterton flue boiler have?

Specification Manufacturer Potterton Flue Type Room-Sealed Fan Fan Assisted Output (KW) 23.5 – 29.3 Boiler ID HHF