Info

The hedgehog was engaged in a fight with

Read More
Q&A

What to do if your prestige solo boiler fails?

What to do if your prestige solo boiler fails?

1. Inspect all piping (water and gas) on the boiler system for leaks and verify that the piping is leak free and properly supported. 2. Inspect the fittings and components on the unit and verify they are leak free. Eliminate all boiler water system leaks. Continual fresh make-up water will reduce the heat exchanger life causing boiler failure.

How big is a triangle tube prestige excellence 110?

Prestige Excellence 110 model by Triangle Tube (ACV) is an Energy Star listed mod-con combi boiler (heat + domestic hot water) with 86 MBTU (Net AHRI) output and ACVMax control.

What should I do to my prestige solo blower?

1. Remove the boiler front jacket panel and ven- turi inlet elbow. 2. Vacuum any dirt or debris from the burner/blower components. 3. Check the burner plate mounting nuts for tightness. 4. Check burner plate gasket for discoloration or damage. Replace gasket if necessary. 5. Re-install venturi inlet elbow. WARNING

Is there any warranty on a triangle tube boiler?

Triangle Tube cannot accept any service or warranty calls from anybody but a licensed technician. Neither we or Triangle Tube can be held liable for improper installation and operation of any Triangle Tube boiler product purchased from our company.

How often should a prestige boiler be serviced?

PRESTIGE Solo 60, 110, Excellence Service Parts Instructions 3 Maintenance Procedures Every PRESTIGE Boiler should be inspected and serviced annually, preferably at the start of the heating season, by a qualified service techni- cian.

How big is a prestige gas solo boiler?

The flagship line of premium condensing firetube gas solo boiler is available in several sizes including 80, 110, 155, 250, 299 and 399. The Prestige features uniquely designed stainless steel heat exchanger and boasts 95% efficiency across the entire range.

How to remove power supply from prestige boiler?

Disconnect the external power supply to the boiler. 2. Remove the front jacket panel of the boiler by removing the thumb screw along the top edge. 3. Remove the electical quick connects on the control and the black plastic housing cover off the control module. Use care not to damage the cover when removing it. 4.

How to use prestige on Boston heating supply?

INTRODUCTION P*0. 1 SERVICING TIPS AND INSTRUCTIONS P*0. 3 CONTROL MODULE DISPLAY – GENERAL P*0. 5 PRESTIGE CONTROL MODULE DISPLAY P*0. 9 SOFT LOCKOUT ERROR CODE P*0. 11 HARD LOCKOUT ERROR CODE P*0. 15 COMBUSTION TEST/SETTINGS P*0. 22 INTERNAL WIRING/ELECTRICAL P*0. 24 REPLACEMENT PARTS P*0. 27 T*+5. 8/ C87=.7=