How do I reset my Baxi boiler after a power cut?

How do I reset my Baxi boiler after a power cut?

To reset the boiler, turn the selector switch to the R (Reset) position. Hold for at least 5 seconds and release. The fault code will be replaced with the boiler’s current temperature. At this point on a neon indicator boiler model, the flame failure light will stop flashing and will be replaced with the burner light.

What number should a Baxi boiler be on?

The normal operating water pressure for your boiler and central heating system is between 1.0 and 2.0 bar. If the pressure drops below 1.0 bar, you need to repressurise it.

Why does the boiler keep cutting out?

If the boiler keeps shutting off, it could be due to closed valves, air caught in the system or a broken pump. The boiler is switching itself off due to in-built safety mechanisms – if it did not shut down, then the boiler could overheat. A closed valve can also prevent water from flowing properly within the boiler.

Should you reset boiler after power cut?

Even though a boiler needs gas to heat water, it won’t run without adequate power. So, how do you rest your boiler even after a power cut? In most cases, you only need to find the reset button and hold it for at least 10 seconds. If the boiler still doesn’t work, you should call a professional to repair it.

What is the optimal temperature for a Baxi combi boiler?

Modern boilers will have a digital dial where you can set the output temperature. For combi boilers it is recommended to set the output temperature for the radiators at 75 degrees and the water temperature at 60 degrees.

What kind of boiler is Baxi solo 3 PF?

1.1 Description 1. The Baxi Solo 3 PF is a gas fired room sealed fan assisted central heating boiler with range rated outputs as shown in the table below 2. Each appliance is preset at a MID RANGE heat input rating and is designed for use on NATURAL GAS only. 3. All boilers are suitable for fully pumped open

What are the requirements for a Baxi boiler?

Baxi Solo 3 80 PF G.C.No. 41 075 09 Baxi is a BS-EN ISO 9001 Accredited Company The boiler meets requirements of Statutory Instrument “The Boiler (Efficiency) Regulations 1993 No3083” and is deemed to meet the

Why does my Baxi solo boiler not light?

Where the pilot lights during the ignition sequence but the main burner does not light there are still 2 or 3 possible causes. The Baxi Solo boilers we see sometimes struggle to go quickly and cleanly from pilot to main burner because there can be significant disturbance of the pilot flame caused by the fan.

Why is my Baxi solo PF not working?

This is a fault we’ve seen before on Baxi Solo PF boilers and is caused by damage to the boiler circuit board (PCB). When we removed the circuit board we found tell-tale damage to one of the soldered contacts of a relay on the board.

What kind of boiler does Baxi solo 3 PF use?

The Baxi Solo 3 PF is a gas fired room sealed fan assisted central heating boiler with range rated outputs as shown in the table below 2. Each appliance is preset at a MID RANGE heat input rating and is designed for use on NATURAL GAS only. 3.

Where the pilot lights during the ignition sequence but the main burner does not light there are still 2 or 3 possible causes. The Baxi Solo boilers we see sometimes struggle to go quickly and cleanly from pilot to main burner because there can be significant disturbance of the pilot flame caused by the fan.

This is a fault we’ve seen before on Baxi Solo PF boilers and is caused by damage to the boiler circuit board (PCB). When we removed the circuit board we found tell-tale damage to one of the soldered contacts of a relay on the board.

Is the Baxi boiler still available in the UK?

Gone are the days where the old, inefficient Bermuda back boilers and fires ruled the day, but despite this, the brand is still going strong, and now they are producing modern, high efficiency A-rated boilers you can rely on – with parts readily available in the UK.