Info

The hedgehog was engaged in a fight with

Read More
Miscellaneous

How do you reset a Sundance spa?

How do you reset a Sundance spa?

Solution: Try turning off the spa for 1-2 minutes, then reboot. This allows ample time for the board to get a full reboot. If problem persists move to next. Temperature overheat, a dirty filter or low flow conditions.

When did Sundance Spas come out with control panels?

Sundance® was one of the first to offer electronic controls on spas. A new technology at the time which is now widely used on most spas today. Sundance Spas came out with their own Spa Side Control Systems and Printed Circuit Boards in 1991. These Spa Side Control Panels are unique to Sundance Spas.

What to do if your Sundance spa switch is defective?

Disconnect wires from Switch terminals. Set ohmmeter in the continuity position. Measure resistance across switch terminals for infinite resistance with pump off. If continuity is measured with pump off, the switch is defective. (Or debris blockage, l which you have to remove switch and inspect.

What is the error code on the Sundance Spa hot tub?

Sn1 Error Code: Heater is deactivated. High-limit sensor located in the heater drywell is nonfunctional. Sn3: Heater is deactivated. Main temperature sensor located in filter bucket is nonfunctional. 6. ILOC Error Code ILOC Error Code: Hot Tub is deactivated.

When did spa side control panels come out?

Sundance Spas came out with their own Spa Side Control Systems and Printed Circuit Boards in 1991. These Spa Side Control Panels are unique to Sundance Spas. This is the first 800 Series Control Systems for Sundance Spas. We stock all Sundance parts. Spa Side Control Panels for Inground Sps.

What to do if your Sundance spa has a PF error?

Should the power return to normal, the PF error will reset itself. If the error returns, contact your Sundance Spa dealer or a qualified service technician. Communication between control panel and/or remove control panel and circuit board is faulty. Contact your Sundance Spas dealer or qualified service technician.

Can a closed flow switch on Sundance Spas be repaired?

CLOSED or SHORTED FLOW SWITCH ON SYSTEM STARTUP (system disabled) Flow switch is non-functional. This must be repaired only be a Sundance Spas dealer or qualified service technician.

What happens when Sundance spa goes into watchdog?

When the spa goes into the Watchdog the spa will not operate. This is how it happens: When you try to use the spa, you will see 3 or 4 dashes on the control panel (depends upon the model). If you try and reset your breaker, sometimes it comes on but it will probably go back into Watchdog error – – – -.

Is the heater disabled on a Sundance spa?

OPEN or SHORTED SENSOR (heater disabled) The main temperature sensor is non-functional. This must be repaired only be a Sundance Spas dealer or qualified service technician. CLOSED or SHORTED FLOW SWITCH ON SYSTEM STARTUP (system disabled) Flow switch is non-functional.